Variable volume chilled water pumping system

Table 1: This table shows the available NEMA motor sizes that are used to size the motors for pumps and fans.

variable primary chilled water sequence of operation

Quickly determine pump sizing and complete pump schedule Section 1. Each of the four categories has their own specific equations, but 1 and 2 are included in the same line item on the calculator The next paragraphs will go through the calculations for each of the four categories.

This total dynamic head is the total pressure drop in the most hydraulically remote run from the chilled water pump supply from the pump to the chilled water return of the pump.

The intersection of the red curve and the green efficiency curves show the efficiency at a certain operating point. If bypass valve maintains a constant flow through the chiller sthere will be no pump energy saved as the loads vary.

chilled water bypass valve operation

Dynamic Viscosity: The dynamic viscosity is used in the calculator to find the Reynolds Number. It is important to note here that this may not be a problem in the systems with variable speed drives on the primary pumps as they will back off on the pressure across the bypass when the system is in low demand conditions where the bypass must operate.

Chillers side is primary loop and the coils side or in other words, the systems side is secondary loop. Whereas, for systems with unequally sized chillers, with more than two chillers or with different chillers, a look-up table is usually required to map minimum flows based on the sum of the minimums from all of the chillers which are operating.

The graph also shows curves of pump horsepower in blue.

Chilled water system diagram

In this case, the service column could be removed since the entire schedule is dedicated to chilled water pumps. The pressure drop through this equipment at a specified flow rate must be provided by the manufacturer of the equipment. The friction calculations are most accurate with fluid flow in the turbulent region. The piping loop for the chillers is known as the primary loop and the piping loop for the system Coils is referred to as the secondary loop. Whereas, for systems with unequally sized chillers, with more than two chillers or with different chillers, a look-up table is usually required to map minimum flows based on the sum of the minimums from all of the chillers which are operating. When you choose the pipe material, pipe type and pipe size, the calculator will automatically determine the inner area from the table within the references. A pipe section is defined as having the same flow rate and same pipe information. Therefore, given the fluctuations and accuracy of controls, a good designer will choose a minimum flow rate which is not very close to the published minimum value. If you select a fluid type from the drop down menu and a temperature, then the calculator will automatically fill in the properties for density, dynamic viscosity and kinematic viscosity.

This figure shows the first half of the schedule. This centrifugal pump type has two chambers split case as opposed to the single chamber for end suction and in-line pumps.

These three K-values are K1, Kinf and Kd.

Chilled water system operating pressure

Here, it can be easily observed that two chillers are attached in parallel arrangement with two cooling loads coils. The piping loop for the chillers is known as the primary loop and the piping loop for the system Coils is referred to as the secondary loop. Figure 8: The top of the calculator summarizes the pressure drop of the hydraulically remote run. The bypass valve will then modulate based on this flow to maintain the minimum flow required across the chiller. And, in addition to pump energy savings, the variable speed drive also improves the controllability at the coil valves and more importantly, at the bypass valve by reducing the pressure differential across the valves. The chilled water pump circulates chilled water through the system. Two-way valves are installed at each coil in order to control the cooling output. Refer to Figure 2 below for an example.